Environmental Aging/Life

Clark's Environmental Lab can test equipment at different temperature and humidity environments to comply with IEEE 323 or any other commercial/military standards (Methods 501.1, 502.1 and 507.1 of MIL-STD-810 and Method 102A of MIL-STD-202D). Environmental chambers of different sizes, including walk-in rooms, are available to perform test programs. Temperature range of +200°F to -200°F and relative humidity range of 40% to 100% can be maintained.
 

ENVIRONMENTAL AGING

Types of Test:

  • Hi-Temp Testing

  • Humidity Testing

  • Low-Temp Testing

  • Salt Testing

  • Thermal Shock Testing

Test Equipment:

1 Vista C-460 Environmental Room

Temp. range -80°C to 90°C
Humidity range 40%-95% RH as limited by 3°C & 50°C Dew points
Int. dimensions 6'-1.5" (W) x 5'-0.5" (D) x 8'-10" (H)

1 Vista C-478 Environmental Room

Temp. range -80°C to 90°C
Humidity range 40%-95% RH as limited by 3°F & 140°F Dew points
Int. dimensions 11'-10.5" (W) x 11'-8" (D) x 12'-4" (H)


Large Walk-In

Temp. range -40°C to +100°C
Int. dimensions 13'10" (W) x 15'9" (L)
Door size 5' (W) x 6'5" (H)


Small Walk-In

Temp. range

-30°C to +100°C

Int. dimensions

4'5" (W) x 5'10" (H)

Door size

10' (W) x 13'5"(H)


Related Testing Services:

Structure & Airborne Noise

  • Sound Pressure Measurements

  • Sound Power Measurements

  • Structure borne Noise Measurements

Corrosion & Salt Spray

  • Salt Spray (fog) & Corrosion testing

  • Qualifications to ASTM B117 to replace 811.1 Federal Test Method

  • Sample Size: 47.5" (L) x 29.5" (W) x 33.5" (D)


LIFE CYCLE

Test Equipment

Life Cycle Oven: 
Grieve B 1-650 Walk-In

Maximum temperature

350°C

Interior dimensions

50" (W) x 47" (D) x 70" (H)



Thermal Shock Chambers: 
Small

Temperature range

-103°F - +400°F

Accepts products

20" Wide and 27" Tall



Medium

Temperature range

-75°F to 350°F

Accepts products

29" Wide and 27" Tall



Thermotron:  Non-Walk-In

Temperature range 4' Wide and 3'11 Tall

HALT CHAMBER

Temperature 
TC/TVC-9

Change Rate Up to 60°C Min
Range -100 to +200°C
Extended Range -150 to +400°C
Temperature Control +-1°C on Stabilization

Tri-Axial Vibration 

TVC-9

Level Up to 60 gRMS
Range 5 to 5000 Hz +-1 gRMS 
Control within 1 min of setting
Max Weight
500lbs

ALTITUDE

Equipment Specifications 
Chamber:

Exterior (Door Closed)  102 1/2" Wide X 95 7/8" Deep X 117 1/2" High
 
Exterior (Door Open) 108 1/4" Wide X 178 1/8" Deep X 117 1/2" High
 
Interior Workspace 72" Wide X 48" Deep X 60" High

Equipment Operating Environment: 

The chamber is designed to operate in the following environment:

  • 0°C to 40°C (32°F to 140°F)

  • 0% to 90% relative humidity, non-condensing

Capabilities

Temp. Range -30°F to +177°C
Humidity Range 20% RH to 95% RH 
(In the temp. range bounded by an 85°C maximum dry bulb temp. & a 4°C minimum dew point.)
Altitude Simulation Range Site to 50,000 Feet
Temp. Control Stability +-1°C as measured at the control/measuring sensor after stabilization. Stabilization occurs when the temp. of the chamber wall liner changes less than 2°C per hour.
Chamber Gradient Not Applicable

Altitude Simulation, Performance: 

Site Level to 50,000 Feet in 16 minutes (3,125Ft/minute)
Static Load 300lbs (100 lbs of each Aluminum, Plastic & Glass)
Live Load N.A. Watts
Make-Up Air N.A. SCFM


Tempature, Performance:

  • -30°C to +20°C in 23 Minutes (2.17°C/Minute)

  • +20°C to +60°C in 23 Minutes (1.74°C/Minute)

  • +60°C to +20°C in 11 Minutes (3.64°C/Minute)

  • +20°C to -30°C in 75 Minutes (0.67°C/Minute)

  • +60°C to +20°C in 13 Minutes (3.08°C/Minute)

Static Load 300 lbs (100lbs each of Aluminum, Plastic & Glass)
Live Load Off 1,500 Watts
Make-Up Air N.A. SCFM



Tempature Humidity, Performance: 

+20°C to +60°C & 75%RH, (+-5%RH) in 23 Minutes (1.74°C/minute)

Static Load 300 lbs (100 lbs each of Aluminum, Plastic & Glass)
Live Load On 1,500 Watts
Make-Up Air N.A. SCFM

FLUID TESTING CLARK TESTING Laboratory Testing Environmental Aging/Life